| Pipe
materials |
Steel |
| Diameter |
HPL-450
(Type 1 liner): 10" - 24" (> 24" upon request for
large projects only)
HPL-180 (Type 2 liner): 6" .-24" (> 24" upon request
for large projects only) |
| Length
|
up
to2,000 ft. per line depending on installation equipment and pipe
diameter |
| Operating
pressure |
high
pressure up to 250 psi for type 1 liner (HPL-450)
high pressure up to 180 psi for type 2 liner (HPL-180) |
| Prerequisites |
Launch
and target pit
Determine condition of pipe, remove any barriers
Statics of pipe body for planned service life
Pipe cleaned and dried
Fill voids for operating pressures above 100 psig |
| Offsets |
Can
be lined depending on size, radius and deflection. |
| Line
condition |
partially
deteriorated gas pipes, e. g. holes up to 2" or gaps up to 1" |
| Tees |
are
opened without excavation trenchless with a robotic cutter equipped
with a CCTV camera |
| Adhesive
system |
epoxy
resin with very long pot life |
| Curing |
Ambient
- no additional equipment required |
| Excavation |
only
one small starting and target pit required per section. An additional
small cleaning pit is only needed for section lengths exceeding 1000
ft. |